This classification is based on the working load the total weight of the cables and the support span the distance between supports.
Cable tray support span.
A support should be located 2 ft.
Support load calculation per iec 61537.
Cable tray is a mechanical support system for cables and raceways.
Intermediate support for upper tray required on piperacks over 6096mm wide.
Cable traysystem component used for cable support consisting of a base with integrated side members or a base connected to side members.
Do not use a cable tray as a walkway ladder or support for people.
Hazardous voltages in electrical equipment can cause severe personal injury or death.
The nema classifications for cable tray were established to simplify and standardize the specification of cable tray.
The support span should not be greater than the straight section length.
The basic types of cable tray supports are.
Cable tray support a device which provides ad equate means for supporting cable tray sections and fittings.
Select tray sizethere are different widths and heights of cable tray and what you require will depend on number size spacing and weight of the cables in the tray.
On each side of an expansion connection.
The nema classes are based on cable loads of 50 75 and 100 per lineal foot.
Cable tray support span the distance between the center lines of supports.
Cable load working load the cable load or the working load is the total weight of the cables to be placed in the tray.
Section 2 manufacturing standards 2 1 materials.
One or more spans iec 61537 7 3i for installations with more than one span it is important to notice that the loading capacity is not the same form one end to the other.
Vertical straight lengths should be supported at intervals dictated by the building structure not to exceed 20 ft.
Snaptrack tray standard 20 lengths.
Vertical cable tray elbows at the top of runs should be supported at the joint on each end.
Cantilever bracket trapeze single rod suspension.
The cable tray institute cti was founded in 1991 to support the cable tray industry by engaging in research development education and the dissemination of information designed to promote enhance and increase the visibility of the industry.
Cable tiesis a type of fastener especially used for binding and organising several cables or wires together or to a cable management system.
The nema standard support spans are based on 8 12 16 and 20.
Support spans support span is the distance between the supports.
Vertical cable tray elbows at the bottom of runs should be supported at the top of the elbow and within 610mm of the joint at the bottom of the elbow.
Evenly distributed load 2 x point load support distance.
Ladder ventilated solid 4.